At the top of the Data window is the control for setting the characteristic value, or CV, of a data group. In this section, the purpose and use of the CV is explained.
The CV is a user-defined number which is associated with the data set and is used for special purposes when evaluating the math expressions associated with def and path parameters. By default, ARTEMIS simply increments the CV value for each data set imported – the first is set to 1, the second to 2, and so on. These values can be changed, but should always be integer-valued.
The CV value is used in two ways to construct rich math expressions and expressive fitting models.
Consider a multiple data set fit to a material measured at various temperatures. For this discussion, let's consider a rock salt structured metal oxide, for instance ZnO. Let's also suppose that we have measured data at three temperatures, 10 K, 300 K, and 500 K.
In a multiple data set fit, you may choose to model the σ² of the first shell Zn-O bond using an Einstein model. This allows you to parameterize the σ² at each temperature as a function of a single variable parameter, the Einstein temperature. To do this, you must define a guess parameter to represent the Einstein temperature like so:
guess thetae = 500
The functional form of the Einstein model takes the variable Einstein temperature and the sample's measurement temperature as its arguments.
path { sigma2 = eins(temp, thetae) }
where temp represents the sample temparature. The pseudo-syntax used here is simply meant to represent the σ² parameter on a the Path page.
In a multiple data set fit, you would have to take care that temp is replaced each time it is used. That could be done in two ways. You could use various set parameters:
set temp1 = 10 set temp2 = 300 set temp3 = 500 path for data set 1 { sigma2 = eins(temp1, thetae) } path for data set 2 { sigma2 = eins(temp2, thetae) } path for data set 3 { sigma2 = eins(temp3, thetae) }
Or you could simply state the temperature explicitly in the path parameter math expressions:
path for data set 1 { sigma2 = eins(10, thetae) } path for data set 2 { sigma2 = eins(300, thetae) } path for data set 3 { sigma2 = eins(500, thetae) }
Both of those solutions work. But neither make effective use of the model building automation in ARTEMIS. In the chapter on the Path window, you learned about various ways of pushing path parameter values onto other paths. One efficient way of setting up a multiple data set fit would be to edit the path parameters for one of the data sets, then push the path parameters onto the other data sets.
Using the two strategies summarized above, you would need to do considerable editing after pushing the path parameter values. That sort of editing is often error-prone.
Here is a third way of solving this problem.
Set the CV for the three data sets to the temperature at which the data were measured. In our example, the three data sets would get CV values of 10, 300, and 500.
Next, edit the σ² path parameter for one of the data sets to read
path for data set 1 { sigma2 = eins([CV], thetae) }
Finally, push this σ² value on the other data sets without editing those to which it is pushed.
When ARTEMIS evaluates the fitting model, it will replace the [CV] token with the appropriate characteristic value. In short, the computer handles the error-prone (for a human) task of editing the many σ² path parameters.
While this may seem like a small improvement over handling the editing chores yourself, use of the CV really pays off for large or complicated fitting models. For a multiple data set fit with many data sets, use of the CV saves quite a bit of editing. Furthermore, you can use the CV value in many path parameter math expressions. For example, suppose you were to model the ΔR values with a temperature-dependent, linear explansion coefficient. The use of the CV in those math expressions saves even more error-prone, manual editing!
The second use of the CV is along with lguess parameters. These parameters are an eficient way of generating per-data-set guess parameters in a multiple data set fit while still making good use of the automation in ARTEMIS for pushing path parameter math expressions between data sets.
Let's again consider the ZnO sample measured at the same three temparatures. This time, however, we choose to float an independent σ² parameter at each temperature.
The straightforward way of doing this would be something like
guess ss1 = 0.002 guess ss2 = 0.004 guess ss3 = 0.006 path for data set 1 { sigma2 = ss1 } path for data set 2 { sigma2 = ss2 } path for data set 3 { sigma2 = ss3 }
Here is how this can be done using the CV and an lguess parameter. First, set the CV values to the temperature values, as before. Next, do the following:
lguess ss = 0.002 path for data set 1 { sigma2 = ss } path for data set 2 { sigma2 = ss } path for data set 3 { sigma2 = ss }
ARTEMIS will notice that ss is an lguess parameter. For each data set in which it is used, ARTEMIS will create a guess parameters named ss_[CV], where, as before, the [CV] is replaced by the CV value.
In the case of our example, three guess parameters will be created called ss_10, ss_300, and ss_500. Each of those will be given the initial value of the coresponding lguess parameter (0.002 in this case). The lguess parameter will not be used in the fit, but each of the generated guess parameters will be floated. At the end of the fit, the log file will report on each as for any other guess parameter.
The utility of the lguess parameter is that it allows you to define a common fitting model used across many data sets. You can use the automation built into ARTEMIS to push those path parameter math expressions between paths and data sets. Without further editing, the desired fitting model – with one guess parameter for each data set – is correctly made.